A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.2.1(a)
|
|
|
A Maintenance Control Program for each unit (see 8.6.1.1.1) shall be provided by the person(s) and/or firm maintaining the equipment and shall be viewable onsite by elevator personnel at all times
|
7/27/2022
|
A17.1-2016 : Elevators
|
5.15 - Overspeed Valve
|
8.6.5.16.5
|
|
|
Overspeed valves, where provided, shall be inspected and tested to verify that they will stop the car, traveling down with rated load, within the specified limits of 3.19.4.7.5(a) using a written procedure supplied by the valve manufacturer or the person or firm maintaining the equipment. If the seal has been altered or broken, the overspeed valve shall be resealed after successful test
|
7/27/2022
|
conversion
|
conversion
|
n/a
|
|
|
Make car top light operational.
|
9/12/2018
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Install door interlock covers.
|
10/23/2018
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Correct issue with car door opening operation.
|
10/23/2018
|