Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Make car top light operational. 9/12/2018
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) A Maintenance Control Program for each unit (see 8.6.1.1.1) shall be provided by the person(s) and/or firm maintaining the equipment and shall be viewable onsite by elevator personnel at all times 7/27/2022
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 Overspeed valves, where provided, shall be inspected and tested to verify that they will stop the car, traveling down with rated load, within the specified limits of 3.19.4.7.5(a) using a written procedure supplied by the valve manufacturer or the person or firm maintaining the equipment. If the seal has been altered or broken, the overspeed valve shall be resealed after successful test 7/27/2022
conversion conversion conversion - reinspect x Install door interlock covers. 10/23/2018
conversion conversion conversion - reinspect x Correct issue with car door opening operation. 10/23/2018