Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A current state operating certificate shall be displayed in machine room in a non-cumbustible frame.
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 No No MCP fire service log must be documented monthly on log sheet.
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) Yes No Car emergency lighting shall work.
A17.1-1996 : Elevators 1.12 - Car enclosure 204 No No All passenger elevator car floors shall be maintained so that persons are not exposed to the hazard of the tripping or falling.
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing (Re-Inspection) Yes No This elevator is equipped with an unsealed overspeed valve and shall have a category 5 test performed in 2022. The overspeed valve shall be tagged and sealed after a successful test. 12/12/2022
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing No No This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve in 2021 or 2022. The valve shall be sealed and tagged after the category 5 test. 12/27/2022
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1 No No The pit shall be kept clean and dry. Remove water from the pit floor. 12/27/2022
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1 No No Pit shall be kept dry. Remove rust from pit equipment, repair/replace as needed, apply rust prevention treatment to all pit steel, investigate/repair water leak. Pit steel starting to delaminate. 12/18/2023
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1206.1h No No Machine room shall have proper fire extinguisher and shall have current monthly/annual test tag. 12/18/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No Permanently mounted pressure gauge shall be replaced with properly calibrated gauge or pressure fitting. 12/18/2023
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1206.7 No No MCP fire service testing must be properly documented monthlty on log sheet. 12/18/2023