MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)8 Car Lighting
|
|
|
The cab ceiling is of the open egg-crate type, which does not provide protection from the light bulbs should they shatter. The lights shall be guarded by plastic sleeve or some other means to properly protect passengers. Repair ceiling tiles so they don't fall on occupants
|
1/3/2024
|
|
A17.1-1996 : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.6.5.16.5 Over Speed Valve Testing
|
|
|
OSV not sealed. Perform test on or before next annual inspection date.
|
3/9/2021
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Need to perform the following tests to complete the Cat 5 inspection: governor pull out and pull through force, check tripping speed of governor switch and governor jaws, set car safeties with rated load at rated speed, check tripping speed of OSV & relief valve pressure. Re-inspection required
|
2/24/2026
|
|
A17.1-1996 : Elevators
|
5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions
|
203
|
x
|
x
|
Car safety mechanism is not functioning and will not apply car safeties in the event of a overspeed condition or broken suspension cables. Red-tagged, removed from service. Re-inspection required
|
2/24/2026
|