Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 111.5 Restricted Opening of Hall/Car Doors x Door restrictor not working. 12/31/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.11.1.4(a) Elevators Placed in Inactive Status x x Car has not been inspected since 12/27/2018 and the last 5 year was performed 11/1/2016. Unit needs to be inactive on state data base and decommissioned or repaired and inspected. 3/18/2026
A17.1-1996 : Elevators 2.13 - Governor,overspeed switch and seal 206 x x Governor will not set safeties. Cable slips through the jaws. 12/31/2025
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 112.3d x x Test of fire service needs to be conducted upon reinspection. 12/31/2025