Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.1 Provide clean down of unit. 8/11/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.12 - Steps, step chains, and trusses 8.11.4.2.12 Observed numerous damaged and broken step demarcation indicators that shall be repair or replaced as needed. 8/11/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.17 - Step/skirt clearances, panels, and performance index 6.1.3.3.5 Unit failed indexing test and shall be repaired and retested. 8/11/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 6.1.3.5 x Observed a broken tread on nose of 1 step, replace as needed. 8/11/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 6.1.3.5 x Repair or replace the broken step tread. 8/16/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 6.1.3.4 (Hand rails) (Re-Inspection) Left side handrail is cracked and shall be repaired or replaced. 8/16/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.19 - Maintenance records 8.6.1.4 A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided. (This item is for notification purposes for future violation in 2022) 11/7/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Certificate A current MO State operating certificate shall be obtained and displayed. 11/7/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.17 - Step/skirt clearances, panels, and performance index 8.6.8.3 Step/Skirt Performance Index x Performance index testing to be performed. 7/17/2024
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.1 Escalator Handrails x Replace the damaged handrail.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.6 Steps x Replace "knife edged" steps.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.13 Escalator Cleaning Unit shall have a clean-down performed. 8/16/2022