ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Certificate
|
|
|
A current MO State operating certificate shall be obtained and displayed.
|
11/7/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.17 - Step/skirt clearances, panels, and performance index
|
6.1.3.3.5
|
|
|
Unit failed indexing test and shall be repaired and retested.
|
8/11/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.3 - Handrails
|
6.1.3.4 (Hand rails) (Re-Inspection)
|
|
|
Left side handrail is cracked and shall be repaired or replaced.
|
8/16/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.9 - Steps and upthrust device
|
6.1.3.5
|
x
|
|
Observed a broken tread on nose of 1 step, replace as needed.
|
8/11/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.9 - Steps and upthrust device
|
6.1.3.5
|
x
|
|
Repair or replace the broken step tread.
|
8/16/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
8.1 - Machinery space access, lighting, receptacle, and condition
|
8.1
|
|
|
Provide clean down of unit.
|
8/11/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
8.12 - Steps, step chains, and trusses
|
8.11.4.2.12
|
|
|
Observed numerous damaged and broken step demarcation indicators that shall be repair or replaced as needed.
|
8/11/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.19 - Maintenance records
|
8.6.1.4
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided. (This item is for notification purposes for future violation in 2022)
|
11/7/2023
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.1 Escalator Handrails
|
x
|
|
Replace the damaged handrail.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.13 Escalator Cleaning
|
|
|
Unit shall have a clean-down performed.
|
8/16/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.17 - Step/skirt clearances, panels, and performance index
|
8.6.8.3 Step/Skirt Performance Index
|
x
|
|
Performance index testing to be performed.
|
7/17/2024
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.6 Steps
|
x
|
|
Replace "knife edged" steps.
|
|