Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Car Operating Panel (COP) lock needs replaced.
A17.1-1996 : Elevators 2.5 - Housekeeping 1001.2(b)(5) Machine room shall not be used for storage. 3/10/2020
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 3/1/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Replace missing COP lock. 3/1/2026
A17.1-1996 : Elevators 2.8 - Pipes, wiring, and ducts 102.1 Non-elevator related wiring shall be relocated and enclosed to conform to NFPA70/NEC. Tele-communication wiring is draped across the machine room, not enclosed, and creating fire penetrations through walls. 3/1/2026
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing This elevator is equipped with an unsealed overspeed valve. The overspeed valve shall be tested with the rated load on for before the next annual inspection. 3/1/2026
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 Required documentation and MCP shall be kept in equipment room including wiring diagrams, oil log, and fire service log recorded monthly. 3/1/2026
A17.1-1996 : Elevators 2.5 - Housekeeping 1206.2b (Clean Machine Room) Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed. 3/1/2026
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x Sprinkler riser shall not run the entire hoistway, 3 floors. Customer may apply for a variance. 3/1/2026
MO Minimum : Elevators (H) - Machine Rooms (H)2 Sump pump discharge pipe runs across elevator machine room close to pump unit and over disconnects; discharge pipe shall be guttered. 3/1/2026
A17.1-1996 : Elevators 2.8 - Pipes, wiring, and ducts 102.2 Non-elevator related wiring shall be relocated and enclosed to conform to NFPA70/NEC. Tele-communication wiring is draped across the machine room, not enclosed, and creating fire penetrations through walls. 3/1/2026
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 3/1/2026