Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems x Door unlocking rollers are missing on 1st and 2nd floor hoistway doors. 8/19/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x Replace missing hoistway door unlocking rollers on first and second floor. 3/1/2021
A17.1-1996 : Elevators 1.15 - sign and operating device symbols 1001.2(a)(15) Need to identify floor lockout keyswitch on car operating panel to corresponding car call that it locks out. 8/26/2020
A17.1-1996 : Elevators 1.15 - sign and operating device symbols 1001.2(a)(15) Need to identify unmarked floor lockout keyswitch located on car operating panel. 8/26/2020
A17.1-1996 : Elevators 2.1 - Access to machine space 101.3d Elevator machine room door needs to be self locking. 8/26/2020
A17.1-1996 : Elevators 2.1 - Access to machine space 101.3d Machine room door needs to be non-defeatable and self locking. 8/26/2020
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.2-211.8 x x Fire service hat lens on car operating panel has been knocked out and is missing. 8/19/2020
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2(c)(5) Written checkout procedure for overspeed valve not on site. Needs to be kept in machine room. 7/15/2022
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.1(a)(1) No documentation of maintenance or testing in on site maintenance record log. 7/15/2022
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters’ Emergency Operation Documentation Test and log firefighter operation monthly 7/15/2022