Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(G) No No Replace broken step tread. Rule 7.9 2/2/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(B) No No Starting key switch needs to be replaced. 2/2/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(G) No No Need to do step indexing. 2/2/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(G) No No Replace broken step tread. 2/2/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(H) No No Lower embark light not working. 2/1/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(E) No No Observed broken tread on one step. 2/1/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.6 Steps Yes No Broken fin on step tread, replace tread. Re-inspection required 4/13/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting Yes No Repair non working lower left embarkation light. Re-inspection required 4/13/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.1.4 Maintenance Records No No A copy of the MCP shall be kept in the machine room 2/2/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.6 Steps Yes No Observed broken tread on step, replace. 5/23/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.6.2(i) Step Demarcation No No Lower left embarkment light not working. 5/23/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(A) Yes Yes Brake test failed, unit removed from service. 5/23/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.13 Escalator Cleaning No No Clean upper and lower pit pans. 5/23/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.6.2(i) Step Demarcation No No Lower left light not working. 5/23/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.6 Steps Yes No Observed broken tread on step, replace. 5/29/2024
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.13 Escalator Cleaning No No Clean both pit pans. 5/23/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting Yes No Repair non working lower left embarkation light. Reported as fixed 5/23/2023 but still existing, re-inspection required. 4/1/2026
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.1.4 Maintenance Records No No Compliant/required documentation shall be kept in equipment room (neat/organized) including MCP, wiring diagrams, PM log, callback log testing logs, etc. Missing MCP for 2022, 2023, & 2024. 4/1/2026
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.13 Escalator Cleaning No No Clean upper pit pan. Excessive metal shaving from steps. Investigate cause, repair, and clean. 4/1/2026
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting Yes No Repair non working lower left embarkation light. Recurring violation/Multiple violation citations, CITED 2025,2023,2022, 2021
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.6 Steps Yes No Step Tread damaged on trailing edge of 1 step. Damaged steps treads should be replaced to conform
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.13 Escalator Cleaning No No Clean Upper Pit Pan.
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate No No Current State Operating Permit shall be displayed in the Equipment Room in a non-combustible frame.
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate No No A current MO State operating certificate shall be posted near the equipment, in a non-combustible frame with a clear protective vision plate over it. 4/1/2026
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate No No Post current Certificate. 5/23/2023
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate No No Post current State Elevator Certificate. 5/23/2023