ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
8.1 - Machinery space access, lighting, receptacle, and condition
|
8.1
|
|
|
Provide clean down of unit.
|
10/1/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
8.12 - Steps, step chains, and trusses
|
8.11.4.2.12
|
|
|
Observed several damaged and broken demarcation indicators that shall be repaired or replaced as needed.
|
8/10/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.3 - Handrails
|
8.11.4.1 (c)
|
|
|
Replace the right side handrail.
|
10/1/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.19 - Maintenance records
|
8.6.1.4
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided. (This item is for notification purposes for future violation in 2022)
|
8/16/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Certificate
|
|
|
A current MO State operating certificate shall be obtained and displayed.
|
8/16/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.3 - Handrails
|
6.1.3.4 (Hand rails) (Re-Inspection)
|
x
|
|
Replace both handrails, large cracks/splits.
|
7/19/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.9 - Steps and upthrust device
|
8.6.8.6
|
x
|
|
8.6.8.6.4 - Replace the damaged "knife-edged" steps. The width or depth of the slots in the tread surface of the steps that do not meet the applicable code requirements shall be repaired or replaced.
|
7/19/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.17 - Step/skirt clearances, panels, and performance index
|
8.6.8.3 Step/Skirt Performance Index
|
x
|
|
Performance index testing to be performed.
|
7/19/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
8.12 - Steps, step chains, and trusses
|
8.6.8
|
x
|
|
Replace broken step demarcation sections
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Certificate
|
|
|
A current MO State operating certificate shall be obtained and displayed.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.13 Escalator Cleaning
|
|
|
Unit shall have a clean-down performed.
|
8/16/2022
|