ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.17 - Door and gate equipment
|
8.6.4.13 Door Systems
|
x
|
|
Basement hoistway doors shall be adjusted so that they are closed at the bottom of the door. Re-inspection required
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.7 - Car door or gate
|
2.14.5
|
|
|
Car doors open too far and create a shear and pinch point.
|
|
A17.1-2016 : Elevators
|
3.17 - Door and gate equipment
|
8.6.4.13
|
|
|
Hoistway door panels shall have 2 gibs mounted on the bottom of each panel
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.28 - Counterweight and counterweight buffer
|
2.21
|
|
|
Repair or replace counterweight sheave. Rope imprinting sheave groove.
|
|
conversion
|
conversion
|
n/a
|
|
|
Replace cap bolt on pick-up roller at level 4.
|
3/14/2019
|
conversion
|
conversion
|
n/a
|
|
|
Replace interlock box cover at level 5.
|
3/14/2019
|
conversion
|
conversion
|
n/a
|
|
|
Replace sight guard on right hoistway door at level B.
|
3/14/2019
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.2.1 Repair Parts
|
|
|
Right car top sheave bearing is going out causing a popping sound. Sheave tracks are also worn down causing ropes to sink into sheave grooves.
|
|
conversion
|
conversion
|
n/a
|
|
|
Shorten hoist ropes, negative cwt. runby and adjust tension between ropes.
|
3/14/2019
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
x
|
x
|
Suspension ropes are severely undersized with rouge. Red tagged, Re-inspection required
|
10/28/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.2.1 Repair Parts
|
|
|
The main traction sheave tracks are worn down causing the ropes to sink into sheave grooves.
|
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)3
|
|
|
There are numerous fire tabs on hoistway doors missing
|
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)3
|
|
|
There are numerous fire tabs on hoistway doors missing
|
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)3
|
|
|
There are numerous missing Fire tabs throughout hoistway, need to be replaced.
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
8.6.4.7 Cleaning of Pits
|
|
|
Water in the pit.
|
|