MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)4
|
No
|
No
|
Machine room is not to be used as a storage closet.
|
|
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
Yes
|
No
|
Emergency light, bell and phone do not work on 110v emergency power. Reinspect in 14 days.
|
4/5/2022
|
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
Yes
|
No
|
Existing phone not working.
|
4/5/2022
|
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1004.2(a)(6) (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
Yes
|
No
|
Repair inoperative emergency phone.
|
8/27/2020
|
|
A17.1-1996 : Elevators
|
3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing
|
1206.2(c)
|
No
|
No
|
Provide standard railing on the car top that meets the code
|
|
|
A17.1-1996 : Elevators
|
5.9 - Buffers and emergency terminal speed limiting devices
|
201
|
Yes
|
Yes
|
Spring buffer stands are rusted and need to be replaced. Red-tagged, removed from service. Re-inspection required
|
|
|
A17.1-1996 : Elevators
|
3.20 - Governor rope
|
206.5
|
Yes
|
Yes
|
Governor rope is rusted and needs to be replaced. Red-tagged, removed form service. Re-inspection required
|
|
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
Yes
|
No
|
Phone was not working at time of inspection.
|
7/7/2022
|