Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.8 - Door closing force 8.11.2.2.8 Yes Yes Need to check door closing force. Did NOT red tag. 11/5/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.18 - Restricted opening of car or hoistway doors 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) Yes No Need to check door restrictor. 11/5/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 4.2 - Hoistway doors 8.11.2.1.4(b) Yes No Need to check hoistway door locks. 11/5/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.11.2.1.4(l) Yes Yes Need to test fireman's service. Did NOT red tag. 11/5/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.6 - Ventilation 2.7.5.2 No No The humidity in the elevator machine room is significantly higher than the elevator controller is designed for due to recent flooding. The humidity in the machine room shall be reduced to proper levels for the elevator controller and other equipment in the machine room to operate as designed. 3/18/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods No No The hydraulic oil in the hydraulic controller for this elevator is milky in color indicating that the oil is contaminated with water. The elevator pump motor on this unit is submersed in oil and will fail with excessive water contamination. The hydraulic oil in this unit shall be changed. 3/18/2026
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current State Elevator Certificate. 3/18/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 2.7.1.1 No No Machine room shall be equipped with a Fire rated access door. 3/18/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No State Certification shall be displayed in machine room. 3/18/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2 Design and Construction of Pits No No Need to check pit switch. 3/18/2026