| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x |  | Emergency phone not working. | 1/29/2020 | 
                
                    | MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x |  | Emergency phone working, but not identifying location. | 2/1/2023 | 
                
                    | MO Minimum : Elevators | (F) - Electrical Switches | (F)2 | x |  | Top directional limit not working. | 2/1/2023 | 
                
                    | MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates |  |  | Fire service plackards missing/damaged at each landing. | 5/15/2024 | 
                
                    | MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers |  |  | Provide a type ABC fire extinguishere in machine room. | 5/15/2024 | 
                
                    | MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) |  |  | Provide MCP in machine room. | 5/15/2024 | 
                
                    | MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers |  |  | Provide a type ABC fire extinguisher in machine room. | 5/15/2024 | 
                
                    | MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records |  |  | Provide an MCP in machine room to log maintenance, repairs, and inspections. | 5/15/2024 | 
                
                    | MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x |  | Emergency phone working, but not identifying the location. | 3/1/2024 | 
                
                    | MO Minimum : Elevators | (H) - Machine Rooms | (H)4 |  |  | Drip pan below pumping unit full, and overflowing onto machine room floor. | 5/15/2024 | 
                
                    | MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | x |  | COP floors 3 & 4 have key switches for security, and not accessible on FFS. | 2/1/2023 | 
                
                    | MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | x |  | COP floors 3 & 4 are key access only, not accessible on FFS without a key. | 9/11/2024 | 
                
                    | MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | x |  | COP on floors 3 & 4 have key switches and are not accessible on FFS II. | 3/1/2024 | 
                
                    | MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate |  |  | Post current operating certificate in machine room. | 5/15/2024 |