Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation Provide on-site maintenance control program. 10/15/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Provide updated documents. 3/14/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.1 Examination and Maintenance Cylinder packing is worn and leaking, repair as needed. 3/14/2024
MO Minimum : Elevators (O) - Existing Hydraulic Elevators (O)4 Control valve on hydraulic pump unit is leaking hydraulic fluid back into tank. Car sank 3" during 15 minute standing test. Repair and reinspect within THIRTY (30) days 4/21/2020
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Provide testing of Phase I &II 11/18/2024
A17.1-2016 : Elevators 11.6 - Temperature/Humidity 2.7.9.2 x Post the temperature and humiodity range for the equipment in the machine room. 12/9/2024
A17.1-2016 : Elevators 4.5 - Access to Hoistway 2.12.7 x The bottom hoistway access switch does not operate. 12/9/2024
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3.2 Phase I Operation Recall by Initiating Device x x Return to test all initiating devices. The alarm company did not have the code for the fire panel. 12/9/2024
conversion conversion conversion - reinspect x Car Re levels, oil bleeding through check balve repair or replace machine room control valve. 7/3/2018