Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (A) - Hoistways (A)1 Floor 1 is missing a fire stop. 12/22/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency light stays on all the time, causing battery to go dead. 9/9/2020
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light does not work. Light fixture is corroded. 4/18/2022
A17.1-1996 : Elevators 1.6 - Car emergency signal 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone does not work. Take corrective action and re-test. 3/25/2025
A17.1-2016 : Elevators 5.15.2 Unsealed Overspeed Valve 8.6.5.16.5 (Re-Inspect) x OSV test must be performed this year. Notice provided on 2020 inspection that valve was not sealed. 4/6/2022