Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No storage in machine room except items related to elevator. 10/1/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No maintenance records on site. 10/1/2020
MO Minimum : Elevators (H) - Machine Rooms (H)2 Repair leaking pipes and protect equipment from water and moisture. 10/1/2020
MO Minimum : Elevators (H) - Machine Rooms (H)2 Repair leaking pipe in machine room and protect equipment from water and moisture. 10/1/2020
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light does not work. 10/1/2020
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Governor rope is severely rouged and needs to be replaced. Re-inspection required 4/8/2024
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Governor rope is severely rouged, needs to be replaced. Re-inspection required 6/10/2024
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)1(A) Install rope data tag on governor rope
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Cat 5 test is incomplete. Need to perform the following tests: check governor rope pull through and pull out force. Check tripping speed of car overspeed governor, test car safeties at rated speed with rated load. Test machine brake with 125% of rated load. Re-inspection required 4/8/2024
conversion conversion conversion - reinspect x Alarm bell shall work 4/26/2018
conversion conversion conversion - reinspect x Phone should call 24 hrs. monitored number, not a recording 4/26/2018
conversion conversion conversion - reinspect x Repair inoperable emergency phone 8/10/2018
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be displayed in the machine room