Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency light not working. 7/22/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No When testing the audible signaling device (alarm bell) with the 110V disconnect in the machine room in the “off” position, the device failed to sound, indicating that the back-up power device (battery) has failed. Repair for proper operation. Reinspection required. 9/20/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No The emergency car lighting is not operational, likely indicating that the back-up power device (battery) has failed. The fixture shall be repaired to operate. Reinspection required. 9/20/2024
MO Minimum : Elevators (O) - Existing Hydraulic Elevators (O)2(B) Yes Yes Upon performing the required annual test, the elevator failed to obtain its rated load pressure. The elevator shall be repaired to obtain rated load pressure and relief pressure as required. If the control valve or the pump motor are required to be replaced, an alteration permit and inspection will be required. 9/20/2024
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Yes No 8.6.4.19.6 The fireman's emergency service phase I and II operations was tested and the following deficiency was noted: Phase II operation did not operate as designed due to multiple programming issues, repair and reinspection is required. 9/20/2024