Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1001.2(d)12 x Phase 2 fire service shall work. 8/22/2019
A17.1-1996 : Elevators 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions 1002.3a x x A category 5 full load test shall be scheduled in the 2019 calendar year. 8/22/2019
A17.1-1996 : Elevators 2.13 - Governor,overspeed switch and seal 1002.3b x x A category 5 full load test shall be scheduled in the 2019 calendar year. 8/22/2019
A17.1-1996 : Elevators 5.9 - Buffers and emergency terminal speed limiting devices 1002.3f x A category 5 full load test shall be scheduled in the 2019 calendar year. 8/22/2019
A17.1-1996 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 1001.2(e)(2) x Provide code compliant minimum counterweight runby. 2/6/2020
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The in car emergency telephone shall be operational. 1/26/2023
A17.1-1996 : Elevators 1.2 - Stop switches 210.2(e) x Replace faulty in-car stop switch. 2/23/2024
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 MCP, including PM records and monthly fire service test log, not being properly documented. 2/28/2024
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits The pit light shall work. 2/28/2024
A17.1-1996 : Elevators 3.10 - Hoistway construction 100 Hoistways shall be of solid construction. Repair hole in hoistway wall (at 3, 4" x 8" hole to pipe chase). 2/28/2024
A17.1-1996 : Elevators 2.5 - Housekeeping 1206.2c (Clean Car Tops) The car top shall be clean. 2/28/2024
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and related on-site documentation shall be provided in the machine room. 2022 MCP records are missing. 2/28/2024
MO Minimum : Elevators (H) - Machine Rooms (H)8 Remove temporary wiring (extension cord) and replace with permanent wiring to meet NEC
A17.1-1996 : Elevators 1.2 - Stop switches 1001.2(a)(2) The in car stop switch is broken. Repair or replace as needed. 1/5/2022
A17.1-1996 : Elevators 2.27 - Rope fastenings 1001.2(b)(25) The wire-rope retaining clips shall be properly installed. At least two wire-rope retaining clips shall be provided to attach the termination side to the load-carrying side of the rope (see Figure 2.20.9.5). The first clip shall be placed a maximum of 4 times the rope diameter above the socket, and the second clip shall be located within 8 times the rope diameter above the first clip. 1/5/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates The hoist rope and governor rope data tags are missing. 1/5/2022
A17.1-1996 : Elevators 2.11 - Disconnecting Means and Control 1001.2(b)(11) The disconnect located in the machine room shall be provided with a sign to identify the location of the supply side overcurrent protective device. 1/5/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Install a code data plate. It shall read: Missouri Minimums & A17.1-1996. 1/5/2022
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits The pit light is broken. Repair or replace as needed. 1/5/2022