A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
1001.2(d)12
|
x
|
|
Phase 2 fire service shall work.
|
8/22/2019
|
A17.1-1996 : Elevators
|
5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions
|
1002.3a
|
x
|
x
|
A category 5 full load test shall be scheduled in the 2019 calendar year.
|
8/22/2019
|
A17.1-1996 : Elevators
|
2.13 - Governor,overspeed switch and seal
|
1002.3b
|
x
|
x
|
A category 5 full load test shall be scheduled in the 2019 calendar year.
|
8/22/2019
|
A17.1-1996 : Elevators
|
5.9 - Buffers and emergency terminal speed limiting devices
|
1002.3f
|
x
|
|
A category 5 full load test shall be scheduled in the 2019 calendar year.
|
8/22/2019
|
A17.1-1996 : Elevators
|
5.2 - Bottom clearance, runby, and minimum refuge space
|
1001.2(e)(2)
|
x
|
|
Provide code compliant minimum counterweight runby.
|
2/6/2020
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
The in car emergency telephone shall be operational.
|
1/26/2023
|
A17.1-1996 : Elevators
|
1.2 - Stop switches
|
210.2(e)
|
x
|
|
Replace faulty in-car stop switch.
|
2/23/2024
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
MCP, including PM records and monthly fire service test log, not being properly documented.
|
2/28/2024
|
A17.1-1996 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
106.1e Illumination of Pits
|
|
|
The pit light shall work.
|
2/28/2024
|
A17.1-1996 : Elevators
|
3.10 - Hoistway construction
|
100
|
|
|
Hoistways shall be of solid construction. Repair hole in hoistway wall (at 3, 4" x 8" hole to pipe chase).
|
2/28/2024
|
A17.1-1996 : Elevators
|
2.5 - Housekeeping
|
1206.2c (Clean Car Tops)
|
|
|
The car top shall be clean.
|
2/28/2024
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
A code compliant MCP and related on-site documentation shall be provided in the machine room. 2022 MCP records are missing.
|
2/28/2024
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)8
|
|
|
Remove temporary wiring (extension cord) and replace with permanent wiring to meet NEC
|
|
A17.1-1996 : Elevators
|
1.2 - Stop switches
|
1001.2(a)(2)
|
|
|
The in car stop switch is broken. Repair or replace as needed.
|
1/5/2022
|
A17.1-1996 : Elevators
|
2.27 - Rope fastenings
|
1001.2(b)(25)
|
|
|
The wire-rope retaining clips shall be properly installed. At least two wire-rope retaining clips shall be provided to attach the termination side to the load-carrying side of the rope (see Figure 2.20.9.5). The first clip shall be placed a maximum of 4 times the rope diameter above the socket, and the second clip shall be located within 8 times the rope diameter above the first clip.
|
1/5/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.7 Signs and Data Plates
|
|
|
The hoist rope and governor rope data tags are missing.
|
1/5/2022
|
A17.1-1996 : Elevators
|
2.11 - Disconnecting Means and Control
|
1001.2(b)(11)
|
|
|
The disconnect located in the machine room shall be provided with a sign to identify the location of the supply side overcurrent protective device.
|
1/5/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.7 Signs and Data Plates
|
|
|
Install a code data plate. It shall read: Missouri Minimums & A17.1-1996.
|
1/5/2022
|
A17.1-1996 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
106.1e Illumination of Pits
|
|
|
The pit light is broken. Repair or replace as needed.
|
1/5/2022
|