Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Up to date operating certificate is required in machine room. 2/3/2023
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1 Front pit sump pump appears to not be working. 2/28/2024
A17.1-1996 : Elevators 3.17 - Door and gate equipment 111 Hoistway doors at floor one need to be adjusted/repaired. Gap approximately 2.5". (Bi-parting freight doors) 2/28/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 The fire extinguisher in the machine room is expired and shall be replace or serviced. 2/28/2020
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1206.1h Machine room shall have proper fire extinguisher and shall have current monthly/annual test tag. 2/28/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.6 - Ventilation 8.11.2.1.2(f) The machine room vent shall be provided with a cover. 2/28/2020
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and related on-site documentation shall be provided in the machine room. 2022 MCP records are missing. 2/28/2024
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 MCP, including PM records and monthly fire service test log, not being properly documented. 2/28/2024
A17.1-1996 : Elevators 2.4 - Machine space 101.2 Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed. Relocate security system from machine room. 2/3/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.4 - Machine space 8.11.2.1.2(d) Seal all machine room penetrations. 2/28/2020
A17.1-1996 : Elevators 2.11 - Disconnecting Means and Control 1001.2(b)(11) The disconnect located in the machine room shall be provided with a sign to identify the location of the supply side overcurrent protective device. 1/5/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 8.11.2.1.2(a) Replace the missing machine room door knob. Must be self-locking type. 2/28/2020
A17.1-1996 : Elevators 2.1 - Access to machine space 1001.2(b)(1) The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. 1/5/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The in car emergency telephone shall be operational with 24/7 support. 2/6/2020
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The in car emergency phone does not work. Initiate the necessary corrective action. 12/28/2021
A17.1-1996 : Elevators 1.6 - Car emergency signal 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Two-way communication device shall work. Main COP ADA/Help phone is not working. AUX COP handset phone does work. Where emergency phones are provided they shall be operational. 2/23/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Replace missing/damaged pickup rollers. 2/28/2024