A17.1-2016 : Elevators
|
2.37 - Pressure Switch
|
8.6.5.14.5
|
|
|
Hydraulic system low pressure switch does not work. Repair
|
6/2/2023
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)6 (Pit Lighting)
|
|
|
Light in pit shall work
|
7/30/2024
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.6.4.19.7 (Re-Inspection)
|
x
|
|
Provide for emergency battery lowering device to work. Re-inspection required
|
7/30/2024
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.6.4.19.7 (Re-Inspection)
|
x
|
|
Re-inspection of auxiliary power lowering unit failed. Auxiliary power lowering unit shall have a set of auxiliary contacts in the mainline disconnect to prevent the car from coming down automatically when mainline power is removed. Re-inspection is required
|
8/28/2024
|
A17.1-1996 : Elevators
|
3.1 - Top-of-car stop switch
|
1001.2(c)(1)
|
|
|
Repair inoperative car top inspection stop switch.
|
6/30/2021
|