MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13 - Door systems
|
|
|
The hoistway door at the 3rd landing is not self-closing/self-locking. The hoistway door shall be adjusted.
|
8/9/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13 - Door systems
|
|
|
A door retaining gib is missing on the 2nd floor hoistway door, a replacement door gib shall be installed.
|
8/9/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13 - Door systems
|
x
|
|
The hoistway door at the 3rd landing is not self-closing/ self-locking. The hoistway door shall be adjusted.
|
8/18/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13 - Door systems
|
|
|
A door retaining gib is missing on the 2nd floor hoistway door, a replacement door gib shall be installed.
|
8/23/2023
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)5 (Machine Room Lighting)
|
|
|
The machine room lighting has been changed to a motion type switch to activate. While this is an energy saving measure, it also is a safety/code concern. Without motion, the switch deactivates the lighting, thereby leaving maintenance personnel with no lighting. Remove motion type switch to a conventional on/off switch.
|
8/9/2023
|
A17.1-1996 : Elevators
|
1.18 - Restricted opening of car or hoistway doors
|
1001.2(a)(18)
|
x
|
|
Replace top floor door restrictor bracket.
|
7/2/2020
|
A17.1-1996 : Elevators
|
3.9 - Floor and emergency identification numbering
|
1001.2(c)(15)
|
|
|
Doors need to have stenciling labeling correct floor
|
5/25/2022
|
A17.1-1996 : Elevators
|
3.9 - Floor and emergency identification numbering
|
1001.2(c)(15)
|
x
|
|
Door needs to have stenciling labeling of correct floor
|
9/22/2021
|
A17.1-1996 : Elevators
|
3.10 - Hoistway construction
|
1001.2(c)(16)
|
x
|
|
Fill hole in hoistway making hoistway fully closed
|
9/22/2021
|
A17.1-1996 : Elevators
|
3.10 - Hoistway construction
|
1001.2(c)(16)
|
|
|
Fill hole in hoistway making hoistway completely enclosed
|
3/25/2022
|
A17.1-1996 : Elevators
|
3.10 - Hoistway construction
|
1001.2(c)(16)
|
|
|
Fill hole in hoistway making hoistway completely enclosed
|
5/25/2022
|
A17.1-1996 : Elevators
|
3.17 - Door and gate equipment
|
1001.2(c)(23)
|
|
|
Top floor is missing a door gib
|
5/25/2022
|
A17.1-1996 : Elevators
|
3.17 - Door and gate equipment
|
1001.2(c)(23)
|
x
|
|
Top floor door is missing door gib
|
9/22/2021
|
A17.1-1996 : Elevators
|
3.23 - Suspension rope
|
1001.2(c)(29)
|
x
|
x
|
Suspension ropes are undersized with rouge. RED TAGGED
|
9/22/2021
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
1206.7
|
|
|
Monthly firefighters service logs shall be maintained on site
|
5/25/2022
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
1206.7
|
x
|
|
Monthly firefighters logs shall be maintained on site
|
9/22/2021
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
1206.7
|
|
|
Monthly firefighters service logs shall be maintained on site
|
3/25/2022
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
The current state operating certificate shall be posted in the machine room in a non-combustible frame.
|
8/9/2023
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
No current certificate on display.
|
7/17/2019
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
The current state operating certificate shall be posted in the machine room in a non-combustible frame.
|
8/23/2023
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A copy of the current state operating certificate shall be on display in the machine room.
|
8/22/2023
|
A17.1-2016 : Elevators
|
5.15 - Overspeed Valve
|
8.6.5.16.5
|
x
|
|
OSV needs to be tested with full load within 90 days
|
9/22/2021
|
A17.1-2016 : Elevators
|
5.15.2 Unsealed Overspeed Valve
|
8.6.5.16.5 (Re-Inspect)
|
x
|
|
OSV must have a cat 5 weight test performed within 90 days or less
|
9/22/2021
|
A17.1-2016 : Elevators
|
5.15.2 Unsealed Overspeed Valve
|
8.6.5.16.5 (Re-Inspect)
|
x
|
|
OSV is not sealed and must have a cat 5 weight test performed within 90 days or less
|
3/25/2022
|