Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(G) Needs step indexing test. 7/17/2019
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.1 Escalator Handrails Repair handrail inlets at bottom of escalator. 3/23/2020
A17.1-2016 : Elevators 8.3 - Controller and wiring 8.6.8.15.3 Replace cover on main control box. 11/3/2020
A17.1-2016 : Elevators 8.8 - Broken step chain device 8.6.8.15.8 x The carriage switch on both sides of the bottom landing do not stop the escalator when actuated. Repair or replace 3/2/2022
A17.1-2016 : Elevators 8.13 - Handrail systems and safety devices 8.6.8.15.13 The handrail inlet switches on the bottom landing do not operate as intended. Repair or replace 3/21/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Testing is incomplete, need to test brake torque, safety switches, comb plate impact switches, missing step switches & hand rail speed sensor. Re-inspection required 9/5/2024
Missouri Minimum : Escalators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Comb impact test failed, adjust as needed.
Missouri Minimum : Escalators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Step indexing test failed, adjust as needed.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.2 Escalator Step-to-Skirt Clearance x Re-adjust left skirt seam joint back to flush state. 8.6.8.3 6/23/2021