Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 Monthly firefighters service logs shall be maintained on site 3/29/2022
A17.1-1996 : Elevators 1.7 - Car door or gate 1001.2(a)(7) There is in a 1" gap in the car right side when closed and door jamb has a sheer in it. REINSPECT REQUIRED 3/29/2022
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 A in car light fixture inside the elevator is not operational and shall be repaired. 8/9/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate The current state operating certificate shall be posted in the machine room in a non-combustible frame. 8/9/2023
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 A in car light fixture inside the elevator is not operational and shall be repaired. 7/27/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate The current state operating certificate shall be posted in the machine room in a non-combustible frame. 7/27/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate The current state operating certificate shall be posted in the machine room in a non-combustible frame 8/9/2023
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No current certificate on display. 7/17/2019
A17.1-2016 : Elevators 5.15.2 Unsealed Overspeed Valve 8.6.5.16.5 (Re-Inspect) x OSV needs to be tested with full load within 90 days or less 3/29/2022
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 111.5 Restricted Opening of Hall/Car Doors x The car door restrictor device shall be adjusted so that it will properly catch and restrict opening of the car doors to a maximum of 4 inches when the car is away from the landing zone. Reinspection required. 11/28/2022