Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems The hoistway door at the 3rd landing site guard at the bottom is damaged and shall be repaired. 8/9/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection There is no packing gland oil catch bucket in the pit on the machine room side. I plastic hose has been installed that goes directly from the packing gland to the hydraulic oil tank in the machine room. The current adopted code requires “oil loss detection” which cannot be obtained with the current method. A oil catch bucket shall be installed and oil loss shall be recorded in the maintenance control program. The hole in the hoistway/machine room wall shall be sealed to maintain the fire resistance rating. 8/9/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems The gap around the door and door frame shall not exceed 1/4 inch 3/26/2024
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) The machine room lighting has been changed to a motion type switch to activate. While this is an energy saving measure, it also is a safety/code concern. Without motion, the switch deactivates the lighting, thereby leaving maintenance personnel with no lighting. Remove motion type switch to a conventional on/off switch. 8/9/2023
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 OSV is not sealed and needs to have a 5 yr full load test. Re-inspection required 3/24/2022
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No current certificate on display. 7/17/2019
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate The current state operating certificate shall be posted in the machine room in a non-combustible frame. 8/9/2023