Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation The traveling cable is damaged and has exposed wires. Check the integrity of the cable and make necessary corrections. 12/9/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) 11/11/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Counterweight spin out cable needs to be replaced and one rope retaining clip is missing. 1/29/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates The fire service phase one key-switch bezel shall be legible. 11/12/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates The fire service phase two key-switch bezel shall be legible. 11/12/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts The counterweight shackle rope tails hit the deflector sheave guard with the car on the compressed air buffer. This shall be corrected. 11/12/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) The pit light shall work. 1/29/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x The annual inspection portion of the test has been completed. The category 5 test shall be completed. (Completed next day by another inspector) 10/11/2022