Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) 11/11/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No Counterweight spin out cable needs to be replaced and one rope retaining clip is missing. 1/29/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No The annual inspection portion of the test has been completed. The category 5 test shall be completed. (Completed next day by another inspector) 10/11/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts No No The counterweight shackle rope tails hit the deflector sheave guard with the car on the compressed air buffer. This shall be corrected. 11/12/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No The fire service phase one key-switch bezel shall be legible. 11/12/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No The fire service phase two key-switch bezel shall be legible. 11/12/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No The pit light shall work. 1/29/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation No No The traveling cable is damaged and has exposed wires. Check the integrity of the cable and make necessary corrections. 12/9/2019