Replace the missing door closer on the machine room It needs to be self closing self latching.
|
8/29/2018
|
conversion
|
conversion
|
n/a
|
|
|
Remove all the stored materials from the machine room
|
8/29/2018
|
conversion
|
conversion
|
n/a
|
|
|
Replace all the electrical wiring and devices located below pit access level with NEMA 4 rated equipment,wet location, that has been under water for a period of time .
|
8/29/2018
|
conversion
|
conversion
|
n/a
|
|
|
Remove the 3 foot plus water from the pit, you have to maintain a dry pit.
|
8/29/2018
|
conversion
|
conversion
|
n/a
|
|
|
Provide an approved pit stop switch
|
8/29/2018
|
conversion
|
conversion
|
n/a
|
|
|
Replace the stop switch in the pit for an approved stop/ run switch per code.
|
8/29/2018
|
A17.1-1996 : Elevators
|
2.5 - Housekeeping
|
1001.2(b)(5)
|
|
|
Clean out the machine room as it is not a storage room for your equipment and materials.
|
8/19/2019
|
A17.1-1996 : Elevators
|
2.7 - Fire Extinguisher
|
1001.2(b)(7)
|
|
|
Have the fire extinguisher re-certified
|
8/19/2019
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Obtain and display a current state operating certificate in the machine room
|
8/19/2019
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Have the emergency phone repaired as there is no dial tone.
|
9/23/2019
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
|
Replace the bad alarm battery
|
9/17/2021
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)6 (Pit Lighting)
|
|
|
Replace the burnt out pit light
|
12/3/2021
|
A17.1-1996 : Elevators
|
3.16 - Traveling cables and junction boxes
|
102.1
|
|
|
The traveling cable is broken and won't let the car run on automatic. The inspection was abborted
|
9/23/2022
|
A17.1-1996 : Elevators
|
2.6 - Ventilation
|
101.5b
|
|
|
Repair the HVAC unit in the machine room.
|
1/8/2024
|
A17.1-1996 : Elevators
|
2.6 - Ventilation
|
101.5b
|
|
|
Repair the non working AC unit in the machine room
|
8/16/2024
|