Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 2.5 - Housekeeping 1001.2(b)(5) Clean out the machine room as it is not a storage room for your equipment and materials. 8/19/2019
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Have the emergency phone repaired as there is no dial tone. 9/23/2019
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1001.2(b)(7) Have the fire extinguisher re-certified 8/19/2019
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Obtain and display a current state operating certificate in the machine room 8/19/2019
conversion conversion n/a Provide an approved pit stop switch 8/29/2018
conversion conversion n/a Remove all the stored materials from the machine room 8/29/2018
conversion conversion n/a Remove the 3 foot plus water from the pit, you have to maintain a dry pit. 8/29/2018
A17.1-1996 : Elevators 2.6 - Ventilation 101.5b Repair the HVAC unit in the machine room. 1/8/2024
A17.1-1996 : Elevators 2.6 - Ventilation 101.5b Repair the non working AC unit in the machine room 8/16/2024
conversion conversion n/a Replace all the electrical wiring and devices located below pit access level with NEMA 4 rated equipment,wet location, that has been under water for a period of time . 8/29/2018
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Replace the bad alarm battery 9/17/2021
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Replace the burnt out pit light 12/3/2021
conversion conversion n/a Replace the missing door closer on the machine room It needs to be self closing self latching. 8/29/2018
conversion conversion n/a Replace the stop switch in the pit for an approved stop/ run switch per code. 8/29/2018
A17.1-1996 : Elevators 3.16 - Traveling cables and junction boxes 102.1 The traveling cable is broken and won't let the car run on automatic. The inspection was abborted 9/23/2022