MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.10 Acceptance Inspection and Test
|
x
|
|
Adjust top floor hoistway access lower limit, cartop to stop level with landing sill.
|
10/8/2025
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.10 Acceptance Inspection and Test
|
x
|
|
Cut off exposed drywall screws from hoistway. Currently cutting hazard for workers.
|
10/8/2025
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.10 Acceptance Inspection and Test
|
x
|
|
Fire caulk/fill holes and voids in hoistway walls around hall station "flex"
|
10/8/2025
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.10 Acceptance Inspection and Test
|
x
|
|
Install smoke detector at 2nd floor landing.
|
10/8/2025
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.10 Acceptance Inspection and Test
|
x
|
|
Plunger packing blew out during stop ring test. Replace and redo stop ring test to verify.
|
10/8/2025
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.10 Acceptance Inspection and Test
|
x
|
|
Test all FAID for function and recall operations (with smoke/heat, no magnet).
|
10/8/2025
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.10 Acceptance Inspection and Test
|
x
|
|
The machine room disconnects shall be labeled with location of feed breakers and purpose (elevator).
|
10/8/2025
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.10 Acceptance Inspection and Test
|
x
|
|
The machine room illumination shall be not less than 10fc at the floor level at the controller.
|
10/8/2025
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.10 Acceptance Inspection and Test
|
x
|
|
The machine room shall have a proper ABC fire extinguisher and shall have a current monthly/annual test tag.
|
10/8/2025
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.10 Acceptance Inspection and Test
|
x
|
|
There are 2 LB electrical box covers missing in the machine room.
|
10/8/2025
|