Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (F) - Electrical Switches (F)1 x Stop switch on car operating panel worn, and not legible. Replace 8/23/2023
MO Minimum : Elevators (F) - Electrical Switches (F)9 Main line disconnect has broken component inside, replace disconnect switch in machine room. 8/1/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Handrail missing in car. 8/1/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods Handrail loose in car. 8/1/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x phone not working not answered 10/23/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Provide a 5 gallon pit jug in pit to collect leakage from jack packing. 8/1/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Position indicator on COP not displaying floor numbers. 8/1/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Provide an MCP in machine room to log maintenance, repairs, and inspections. 8/1/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 Remove sprinkler head from ceiling above controller, no heat detector or shunt trip present. 8/1/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 machine room door not self locking provide self looking door handle 8/25/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 mach. room door lock defeatable 10/24/2023
MO Minimum : Elevators (I) - Pits (I)1 Debris in pit. 8/1/2023
A17.1-2016 : Elevators 2.36 - Hydraulic Cylinders 8.6.5.14.2 Hydraulic Cylinders and Pressure Piping x x leak down test failed dropped 2 inches in 15 mins futher testing required no shutoff valve 10/23/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current operating certificate in machine room. 8/1/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate no current cirt displayed 10/24/2023