Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 5.11 - Plunger and Cylinder 8.6.5.11 REPLACE NORTH LEAKING JACK PACKING
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 x TEST OVERSPEED VALVE (UNSEALED). REINSPECTION REQUIRED WITHIN 30 DAYS
A17.1-2016 : Elevators 6.1 - Operation of elevators under fire and other emergency conditions (A17.1b-1973 through A17.1b-1980) 8.6.11.1 Firefighters’ Emergency Operation x REPAIR PHASE 2 FIRE SERVICE OPERATION. PHAS 2 DOES NOT OVER RIDE KEYED OUT FLOOR SWITCHES. REINSPECTION REQUIRED WITHIN 30 DAYS.
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits REMOVE WATER FROM THE PLIT. MEANS SHOULD BE PROVIDED TO PREVENT ACCUMULATION OF THE WATER.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Provide a maintenance control program on site 5/11/2021