Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No The elevator ADA telephone inside the elevator is not working properly. Two-way communication could not be established. Repair/replace this phone for proper operation and passenger safety. Reinspection required. 3/31/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) Yes No The car door operator was out of service and full inspection on the car door operation could not made. Repair car door operator and a reinspection is required to ensure proper operation. 3/31/2026
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) Yes No This elevator has a backup emergency generator power that is used in case of a power outage. This system shall be scheduled to be tested and a reinspection is required. This requirement is due to the State of Missouri adopting the A17.1 2016 version of the elevator safety code. Reinspection required. 3/31/2026
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Means of two way communication are inoperable and shall be repaired or replaced. 2.27.1 9/30/2025
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Reprogram emergency phone. 4/7/2022
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Means of two way communication are inoperable and shall be repaired or replaced. 4/7/2026
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Means of two way communication are inoperable and shall be repaired or replaced. Re-inspection required
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Two way communication inoperable. Re-inspection required 12/10/2024
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Means of two way communication are inoperable and shall be repaired or replaced. 3/11/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Inspection incomplete. Must perform all the weight test, counter weight buffer, set safeties, 125% brake test 12/19/2024
A17.1-1996 : Elevators 2.6 - Ventilation 1001.2(b)(6) No No Repair air conditioning in machine room. 9/30/2025
A17.1-1996 : Elevators 2.6 - Ventilation 101.5b No No Permanent means of temperature control are inoperable and shall be repaired, or replaced. 9/30/2025
A17.1-1996 : Elevators 2.6 - Ventilation 101.5b No No Permanent means of temperature control are inoperable and shall be repaired, or replaced. 9/30/2025
A17.1-1996 : Elevators 2.6 - Ventilation 101.5b No No Permanent means of temperature control are inoperable and shall be repaired, or replaced. 3/31/2026
A17.1-1996 : Elevators 2.6 - Ventilation 101.5b No No Permanent means of temperature control are inoperable and shall be repaired, or replaced. 4/7/2026
A17.1-1996 : Elevators 3.17 - Door and gate equipment 1001.2(c)(23) No No Refasten loose, bottom terminal floor hoistway door sight guard. 3/31/2026
A17.1-1996 : Elevators 3.17 - Door and gate equipment 1001.2(c)(23) No No Refasten loose, bottom terminal floor hoistway door sight guard 9/30/2025
A17.1-2016 : Elevators 4.2 - Hoistway doors 8.6.4.13 Door Systems No No Bottom hoistway door sight guard (non vision panel) is loose, needs repaired
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits No No Clean rubbish from pit. 9/30/2025
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 1206.2a Yes No Clean debris from elevator pit. 1/16/2020
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 1206.2a (Pits and Hoistways) No No Clean pit. 9/30/2025
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.7 Firefighter' Service Operating Procedures Yes No Phase 2 call cancel is inoperable and shall be repaired or replaced. 3/11/2025
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.7 Firefighter' Service Operating Procedures Yes No Fireman’s service operation could not be completed due to the car door operator being out of service. Repair door operator to fireman’s service. Reinspection is required. 3/31/2026
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.4.19.6 Yes No Call cancel does not work on phase II fire service, needs repaired. Re-inspection required