Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation A written maintenance control program shall be kept on site for each elevator.
MO Minimum : Elevators (I) - Pits (I)1 Clean trash from Elevator pit.
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) x Emergency lighting shall work. Only one bulb is working. 5/28/2024
A17.1-1996 : Elevators 3.12 - Pipes, wiring, and ducts 1001.2(c)(18) Install cover on open electric box at 2nd floor in hoistway and missing duct cover at top hoistway. 6/1/2020
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 MCP, including PM records and monthly fire service test log, not being properly documented.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Phone in elevator cab does not work. 4/26/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light shall be guarded.
A17.1-1996 : Elevators 3.26 - Broken rope, chain, or tape switch 1001.2(c)(9) x Repair safety switch on counterweight safety 3/20/2020
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.8 Switch Keys Replace mislabeled Phase I fire service key switch. 6/1/2020
A17.1-1996 : Elevators 3.23 - Suspension rope 206.7 x x Suspension ropes need replacement. Red tagged unit. 3/20/2020
MO Minimum : Elevators (A) - Hoistways (A)16 Wireway between 14 & 15 is missing cover.