Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 3.28 - Counterweight and counterweight buffer 201 Counterweight roller is dragging. Repair or replace.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Cartop inspection intermittently does not work.
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light shall work. It is broken, the car hits the guard.
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 MCP, including PM records and monthly fire service test log, shall be present.
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.8 Switch Keys Replace mislabeled Phase I fire service key switch. 6/1/2020
A17.1-1996 : Elevators 3.29 - Counterweight safeties 1001.2(c)(14) x x Counterweight safety is not working. Red tagged elevator. 4/13/2021