conversion
|
conversion
|
n/a
|
|
|
Both Bottom and top demarcation lights not working
|
5/13/2020
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2(K)
|
|
|
Left handrail needs to be replaced.
|
5/13/2020
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2(E)
|
|
|
Missing comb teeth
|
5/13/2020
|
Missouri Minimum : Escalators
|
11 CSR 40-5.090 Inspection and Testing
|
8.6.11.6.1(b)(Not accessible to public)
|
|
|
The escalator has been placed out of service and is being used as a means of egress. The escalator shall be either returned to service or properly barricaded to prevent the public from using the escalator as a stairway.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.1.4 Maintenance Records
|
|
|
There shall be maintenance records kept in the escalator machine space accessible to the inspector depicting dates and descriptions of maintenance tasks performed, callbacks, examinations, tests, adjustments, replacements and wiring diagrams. This shall be in accordance to the requirements in the Maintenance Control Program.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.11.6.2(i) Step Demarcation
|
|
|
The bottom demarcation light fixture was inoperative and shall be repaired to illuminate.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2(F)
|
|
|
A substantial gap is in the glass balustrade at the top of the escalator. Adjust the glass balustrade to minimize the gap.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.2 Escalator Step-to-Skirt Clearance
|
x
|
|
The step/skirt index is at too great of a gap and coefficient. Adjust step/skirt index to be under the maximum limits.
|
|