Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) A written Maintenance Control Program shall be in place to maintain the equipment in compliance with the requirements of Section 8.6
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(H) Top and bottom demarcation lights don't work 4/20/2020
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(D) x Missing step switch doesn't work 7/2/2021
A17.1-2016 : Elevators 7.3 - Handrails 8.6.8.1 x The left handrail has a large crack. The handrails, including splices and joints, should be free of any cuts, cracks, gouges, pinch points, or any other condition that would be a hazard to passengers.
conversion conversion n/a Adjust handrail drive chain - Excessive slack 4/20/2020
conversion conversion n/a Top and bottom demarcation lights don't work 4/20/2020