Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Emergency two way communication phone does not operate. If not repaired in 14 days car will be red tagged and removed from service for consecutive years of violation
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Emergency phone is not working. Re-inspection required 7/5/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Phone in elevator cab does not work. Re-inspection required 8/2/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Phone in elevator cab not working Reinspection required 6/27/2024
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Emergency phone in cab is not working. Re-inspection required 6/27/2024
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Emergency two way communication device does not operate. Repair and reinspect 7/31/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Yes No Scavenger pumps that do not record the amount of oil returned to the hydraulic tank shall not be installed in elevator pits. Install a maximum of a 5 gallon container in elevator pit to record oil loss
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) Yes No Door restrictor on the rear doo is inoperable
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection No No Scavenger pumps that do not record the amount of oil returned to the hydraulic tank shall not be installed in elevator pits. Install a maximum of a 5 gallon container in elevator pit to record oil loss
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection No No Scavenger pumps that do not record the amount of oil returned to the hydraulic tank shall not be installed in elevator pits. Install a maximum of a 5 gallon container in elevator pit to record oil loss
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection No No Scavenger pumps that do not record the amount of oil returned to the hydraulic tank shall not be installed in elevator pits. Install a maximum of a 5 gallon container in elevator pit to record oil loss
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) Yes No Rear car door restrictor does not work, needs repaired. Re-inspection required 8/2/2023
MO Minimum : Elevators (I) - Pits (I)1 No No Need to clean oil from elevator pit
MO Minimum : Elevators (I) - Pits (I)1 No No Pit has oil & water covering floor
MO Minimum : Elevators (I) - Pits (I)1 No No Elevator pit has what appears to be water and/or oil in it. Pit shall be kept clean and dry
MO Minimum : Elevators (I) - Pits (I)1 No No Need to clean oil from elevator pit
MO Minimum : Elevators (I) - Pits (I)1 No No Elevator pit has what appears to be water and/or oil in it. Pit shall be kept clean and dry
MO Minimum : Elevators (I) - Pits (I)1 No No Clean oil from elevator pit
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing No No OSV is due for full load test and tripping speed checked. On or before the next inspetion
conversion conversion n/a No No Pit shall be kept dry. 10/28/2020