Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 2.39 - Low Oil Protection 306.16 No No Door open button shall stay active after low oil timer is active. Reinspect 11/19/2019
A17.1-1996 : Elevators 2.39 - Low Oil Protection 306.16 No No Repair low oil system. Car lowers to the lowest level which is a secure floor after timeout. If door closes, you cannot reopen the door without the security code creating a trap hazard. 11/19/2019
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Display current operating certificate in machine room. 4/16/2021
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing No No OSV not sealed. Perform OSV test on or before next annual inspection. 4/16/2021
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 No No A fire extinguisher with a current inspection date shall be placed in the machine room 5/12/2025
MO Minimum : Elevators (I) - Pits (I)1 No No The elevator pit has quite a bit of liquid in it, the liquid needs to be pumped out and determined where it is coming from and repaired 5/12/2025
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency phone shall be programmed to answering service that will answer 24/7, this unit has kingsIII that is not being answered 5/25/2023
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) Yes No Auxiliary lowering shall be made operable. Found that there is no switch in the disconnect to let the controller not to run when the power is turned off intentionally. 5/25/2023