Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Phone in elevator cab does not work. 9/11/2018
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The in car emergency telephone shall be operational. 11/6/2020
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 9/28/2023
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1 The pit lighting shall be increased. The lighting shall provide an illumination of not less than 10 foot-candles at the pit floor and at a pit platform, when provided. 7/20/2022
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 Missing light covers in the car.
A17.1-1996 : Elevators 1.12 - Car enclosure 204 204.1b - Missing ceiling tiles in the car.
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1 Water and oil shall not be allowed to accumulate on the pit floor.
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
A17.1-1996 : Elevators 1.12 - Car enclosure 204 Repair drop ceiling or protect light bulb in fixtures. Cited multiple years. Ceiling grid does not properly secure tiles. Lamps shall have protective clear tubes to prevent broken glass from falling onto passengers.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Jack drain tubes, from wiper ring, shall be routed to measurable container in pit, not to exceed 5 gallons per jack. See State Memorandum 006.
MO Minimum : Elevators (A) - Hoistways (A)16 Pit FAID device (Smoke/heat detector) is damaged. Repair/replace as need.
conversion conversion n/a Repair drop ceiling or protect light bulb in fixtures 8/24/2018
conversion conversion n/a Excessive leaking on cylinder packings 8/24/2018
conversion conversion n/a Phone shall work 8/24/2018
conversion conversion n/a car top shall be kept clean 8/24/2018
conversion conversion n/a Pit shall be clean and dry 8/24/2018