Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) x Test operation of elevator on emergency power with an inspector present 10/28/2022
A17.1-2016 : Elevators 1.8 - Door closing force 8.6.4.19.8 x Door pressure exceeds 30# 10/28/2022
A17.1-2016 : Elevators 1.8 - Door closing force 8.6.4.19.8 x Door force exceeds 30 pounds 10/25/2023
A17.1-2016 : Elevators 2.36 - Hydraulic Cylinders 8.6.5.5.1 Examination and Maintenance Replace plunger seal. Seal leaks excessively 2/1/2024
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.1(a)(1) MRL not up to date 2/1/2024
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(c) Test and log firefighter operation monthly 11/17/2020
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2(b)(4) Post emergency evacuation of passengers procedure inside machine 11/17/2020
A17.1-2016 : Elevators 2.5 - Housekeeping 8.6.4.8 Machine Room and Machinery Space Remove non-elevator related material from elevator machine room 11/17/2020
A17.1-2016 : Elevators 5.11 - Plunger and Cylinder 8.6.5.5 Cylinder drain line shall drain into pit collection container of no more than 5 gallon container. Remove scavenger pump from pit. 11/17/2020
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.8 Switch Keys Install FEO-K1 keyswitches. All elevators in the same building shall have firefighter keyswitches operable by the same key. 10/28/2022
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state operating certificate inside machine room 11/17/2020
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate State operating certificate not displayed 1/5/2024