Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Pit light not working 7/17/2019
conversion conversion n/a The mechanical re-open device on both front and rear doors are not working 7/17/2019
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Emergency light not working. 7/17/2019
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Emergency bell not working. 10/22/2019
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)2 Front car gate safety edge boot needs to be replaced. 1.7 7/17/2019
MO Minimum : Elevators (A) - Hoistways (A)6 Hoistway unlocking device shall be locked. 6/2/2021
MO Minimum : Elevators (A) - Hoistways (A)6 Top and bottom floor hoistway unlocking devices shall be locked shut at all times 4/15/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Emergency alarm does not work 12/23/2021
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x x All suspension rope diameter severely undersized 12/23/2021
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Monthly firefighters service logs shall be maintained onsite 4/15/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x The emergency car lighting is not operational, likely indicating that the back-up power device (battery) has failed. The fixture shall be repaired to operate. Reinspection required. 11/28/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x When testing the audible signaling device (alarm bell) with the 110V disconnect in the machine room in the “off” position, the device failed to sound, indicating that the back-up power device (battery) has failed. Repair for proper operation. Reinspection required. 11/28/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts The elevator car gate safety boot on the rear opening has deteriorated beyond operating correctly and shall be replaced. 7/27/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers The fire extinguisher in the machine room shall be serviced, the last annual service tag indicates it was serviced in 2021. 7/27/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts The dead end hitch has a spring that is broken in the machine room that shall be replaced for the hoisting ropes to have an equal amount of tension. 7/27/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts The HVAC unit in the machine room shall be repaired to provide proper operation temperature for the elevator controller. 7/27/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts The elevator car gate safety boot on the rear opening has deteriorated beyond operating correctly and shall be replaced. 7/27/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers The fire extinguisher in the machine room shall be serviced, the last annual service tag indicates it was serviced in 2021. 7/27/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts The dead end hitch has a spring that is broken in the machine room that shall be replaced for the hoisting ropes to have an equal amount of tension. 7/27/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts The HVAC unit in the machine room shall be repaired to provide proper operation temperature for the elevator controller. 7/27/2023