Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.4 - Machine space 2.7.1.1 No No Repair hole in machine room wall around sump pump piping
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 8.11.2.1.2(a) No No Machine room door has no self-closing features. Remove door key from lobby side firefighters box at lower landing and keep in secured location.
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room door must be self closing and lockable.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Fill holes around piping in machine room.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No Fire extinguisher in machine room is expired, needs to be replaced or have serviced
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room door shall be self locking & self closing
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Emergency phone in car is unable to provide location, needs to be upgraded to do so. Re-inspection required 8/16/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room door shall be self closing & self locking
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces No No Need to repair hole in machine room wall around sump pump piping
MO Minimum : Elevators (H) - Machine Rooms (H)2 Yes No Provide machine room door to be self closing and self locking. 8/25/2025
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Phone works, but unable to communicate (bad number). Reprogram phone. 8/25/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces Yes No Seal hole in machine room around sump pipe. 8/25/2025
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting No No Car has egg crate type ceiling tiles. Provide guards on bulbs to prevent accidental contact or breakage.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No Fire extinguisher in machine room expired 2023. Fire extinguisher shall be kept up to date yearly