Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.5 - Car lighting and receptacles 2.14.7.4 Protection of Light Bulbs and Tubes Cab ceiling diffuser panel is missing. Replace diffuser panel or install bulb guards on fixture.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Ceiling tile (light diffuser lens) missing from car .
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Ceiling tile in cab is missing.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.12 - Car enclosure 8.11.2.1.1(l) Ceiling tile missing in cab.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone shall work. 2/12/2019
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room door is to be self closing and self locking.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 8.11.2.1.2(a) Machine room door strike plate has been removed. Replace
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits Observed standing water in the pit, determine if the sump pump is working,
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current State Elevator Certificate.