Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion conversion - reinspect x Emergency phone not working on battery 1/2/2020
conversion conversion n/a Replace hoist cables 1/2/2020
conversion conversion conversion - reinspect x Emergency alarm not working 1/2/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency alarm bell does not work on battery back-up. 1/27/2022
MO Minimum : Elevators (I) - Pits (I)1 The pit needs to be cleaned. 8/18/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Annual inspection not complete. Test car and counterweight buffers. 1/27/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x The in car emergency lighting shall be operational. 10/26/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 8/18/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x The in car emergency alarm bell shall be operational. 8/31/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x The in car emergency light shall be operational. (2nd Notice) 8/31/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) x Replace missing fire tabs on hoistway doors (14th floor). 10/8/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) A code compliant MCP and all the on-site documentation required shall be provided in the machine room. No MCP and fire service testing logs, which shall be documented monthly.
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room door shall be self-closing and self-locking. Latch does not catch strike-plate.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars Car top shall be kept clean.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)3 Top emergency exit shall be properly secured. The latches are broken.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.7 Cleaning of Hoistway and Pit Hoistway doors needs to be cleaned. Door and related hardware are covered in oily lint.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
MO Minimum : Elevators (I) - Pits (I)1 Pit shall be kept clean and dry. Remove excess debris and repair source of water leak.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)3 x Top emergency exit shall be properly secured. The latches are broken. This item requires a re-inspection as it is a repeat violation.