Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 An MCP shall be in place as specified in A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 1/31/2022
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve on or before the next annual inspection. The valve shall be sealed and tagged after the category 5 test. 1/31/2022
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 1/31/2022
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing (Re-Inspection) x This elevator is equipped with an overspeed valve that in not sealed. A category 5 test shall be performed on the overspeed valve. The valve shall be sealed and tagged after the category 5 test. 9/19/2022
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equippment room in a non-combustible frame with a clear protective vision plate over it. 1/21/2026
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1001.2(b)(7) An ABC type fire extinguisher with a current test tag shall be mounted convenient to the machine room door. 1/21/2026
A17.1-1996 : Elevators 2.35 - Supply Line and Shutoff Valve 303 The oil line shut off in the machine room cannot be moved from the open position. This shall be corrected. 1/21/2026