Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Remove old light fixtures and cieling tile that are being stored inside elevator machine room. 6/22/2018
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Post firefighter operating instructions next to hall fire keyswitch 7/21/2022
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room access door needs to be self closing, and self locking. Door lock needs to be non-defeatable 8/10/2021
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room access door needs to be self-closing 7/21/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Post In Case of Fire signage next to corridor call station at each landing 7/21/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Provide cylinder drain line pit collection containers. Seperate container for each cylinder. 8/10/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Replace firefighter keyswitch bezel on phase 1 keyswitch. Identification markings on the bezel are illegible. 7/21/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency phone does not operate 7/8/2024