Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 3.19 - Guide rails fastening and equipment 1001.2(c)(25) 200.7b(1)(c) The guide rail fishplate is missing a bolt the right side looking in the hoistway between the 1st and 2nd landing.
A17.1-1996 : Elevators 1.4 - Sills and car floor 1001.2(a)(4) 204.2b Flooring has been added that interferes with the opening of the car operating panel denying access to the emergency battery for the alarm bell and emergency lighting. Readjust flooring or car operating panel.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers The fire extinguisher in the machine room shall be serviced, the last annual service tag indicates it was serviced in 2022.
A17.1-1996 : Elevators 1.16 - Rated load, platform area, and data plate 207 There is no car capacity plate inside the elevator stating the rated load of the car, as required.
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Bell not working.
A17.1-1996 : Elevators 1.7 - Car door or gate 112.2a Elevator will run with car gate open 3 1/2". Maximum opening is 2". Reinspect within 30 days. 11/5/2020
A17.1-1996 : Elevators 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing 1206.2(c) Clean elevator car top. 11/5/2020
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing OSV installed and not sealed. Perform OSV test on or before next annual inspection. 4/28/2021
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1206.1h Expired 9/1/2022
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits Provide working pit light. 9/1/2022
A17.1-1996 : Elevators 5.11 Plunger and Cylinder 1206.5b(4) Packing (left jack) worn and leaking. 9/1/2022
A17.1-1996 : Elevators 1.8 - Door closing force 1001.2(a)(8) x Door force exceeds 30#. 9/1/2022
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The elevator alarm bell inside the elevator is not working. Check and repair the alarm bell for proper operation and passenger safety. Reinspection required. 11/12/2024
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The elevator alarm bell inside the elevator is not working. Check and repair the alarm bell for proper operation and passenger safety. Re-inspection required 12/10/2024