Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Provide existing alarm bell to work.
A17.1-1996 : Elevators 1.4 - Sills and car floor 1001.2(a)(4) 204.2b Flooring has been added that interferes with the opening of the car operating panel denying access to the emergency battery for the alarm bell and emergency lighting. Readjust flooring or car operating panel.
A17.1-1996 : Elevators 1.8 - Door closing force 1001.2(a)(8) x Door force exceeds 30#. 9/1/2022
A17.1-1996 : Elevators 3.19 - Guide rails fastening and equipment 1001.2(c)(25) 200.7b(1)(c) The guide rail fishplate is missing a bolt the right side looking in the hoistway between the 1st and 2nd landing.
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits Provide working pit light. 9/1/2022
A17.1-1996 : Elevators 1.7 - Car door or gate 112.2a Elevator will run with car gate open 3 1/2". Maximum opening is 2". Reinspect within 30 days. 11/5/2020
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1206.1h Expired 9/1/2022
A17.1-1996 : Elevators 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing 1206.2(c) Clean elevator car top. 11/5/2020
A17.1-1996 : Elevators 5.11 Plunger and Cylinder 1206.5b(4) Packing (left jack) worn and leaking. 9/1/2022
A17.1-1996 : Elevators 1.16 - Rated load, platform area, and data plate 207 There is no car capacity plate inside the elevator stating the rated load of the car, as required.
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The elevator alarm bell inside the elevator is not working. Check and repair the alarm bell for proper operation and passenger safety. Reinspection required. 11/12/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers The fire extinguisher in the machine room shall be serviced, the last annual service tag indicates it was serviced in 2022.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Provide current year tested fire extinguisher in the elevator machine room.
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The elevator alarm bell inside the elevator is not working. Check and repair the alarm bell for proper operation and passenger safety. Re-inspection required 12/10/2024
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Bell not working. 3/5/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.7 Cleaning of Hoistway and Pit Clean the pit.
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing OSV installed and not sealed. Perform OSV test on or before next annual inspection. 4/28/2021